BS 7671 Amendment 4 Explained: What It Means for Your Home

Practical advice from Sparcford in Kingston

The short answer: Amendment 4 to BS 7671, the IET Wiring Regulations, was published on 15 April 2026 and has been the version electricians must work to since 15 October 2026. It is not retrospective, so you do not have to upgrade your electrics because of it. The change most homeowners will notice is a new chapter on home battery storage, and the fire safety rules that go with it keep batteries out of lofts, bedrooms and escape routes. Despite what you may read online, arc fault detection devices (AFDDs) are not one of the headline changes.

Here is what changed, when it applies, and what it actually means for your home.

What is BS 7671?

BS 7671, Requirements for Electrical Installations, is the UK national standard for electrical installations. It is published jointly by the Institution of Engineering and Technology (IET) and the British Standards Institution (BSI), and electricians often call it “the regs”.

According to the IET, it covers:

  • all new low voltage electrical installations
  • additions and alterations to existing installations
  • periodic inspection and testing of existing installations

The current edition is the 18th Edition, BS 7671:2018. Rather than publishing a whole new edition every time something changes, the IET and BSI issue amendments. Amendment 4 is the latest, and its full name is BS 7671:2018+A4:2026. The IET calls the printed version the Orange Book.

Key dates

DateWhat happened
15 January 2026The IET and BSI signed off the content of Amendment 4
15 April 2026Amendment 4 published and available to use
15 October 2026The previous version (BS 7671:2018+A2:2022+A3:2024) withdrawn. Amendment 4 must be used from this date

The six months between publication and withdrawal gave electricians time to get familiar with the changes. The dates are set out in the IET’s Wiring Matters and confirmed on the BSI listing for the standard.

What changed in Amendment 4?

The IET and BSI list these as the main changes:

  • A new chapter on stationary secondary batteries, meaning batteries used to store energy and supply an electrical installation. This is home battery storage, with or without solar panels.
  • A new section on functional earthing and bonding for IT and communications equipment.
  • A new section on Power over Ethernet (PoE), where low voltage DC power travels over data cabling to things like LED lighting and small devices.
  • A major revision of the rules for medical locations such as hospitals and clinics.
  • Amendment 3 (2024) folded into the main document, so there is one complete book again.

The IET also notes that there are further changes throughout the standard. Most of them are technical and will not change anything you see at home. For homeowners, the battery chapter is the one that matters.

Home batteries: the biggest change for homeowners

Home batteries are becoming common, often alongside solar panels and increasingly with electric vehicles. Until now BS 7671 had no dedicated chapter for them. The IET says the new chapter covers system design, inverters and whether protective devices are suitable for power flowing in both directions. It also “places strong emphasis on safety-critical matters such as appropriate battery location, ventilation, and fire-risk mitigation”.

For homes, the detailed location rules come from a separate BSI document, PAS 63100:2024, published in March 2024. It is a fire safety specification for battery storage in dwellings. When the IET described the draft of Amendment 4 in 2024, it said the new chapter would require batteries in dwellings to be installed in accordance with PAS 63100. In a summary of the published text for Professional Electrician, Steve Humphreys of NAPIT describes the final regulation as requiring batteries in dwellings to be installed in a suitable location “taking account of PAS 63100”.

Can a battery go in the loft?

No, not under PAS 63100. Its starting point is that “the best place for storage batteries is outside dwellings and away from habitable rooms”. Where it is practicable, batteries shall be installed outdoors. The PAS also lists places where batteries shall not be installed, including:

  • rooms where people sleep
  • escape routes, including landings, staircases and corridors
  • storage cupboards or spaces that open into a bedroom
  • voids, roof spaces or lofts
  • within 2 m of stored flammable materials or fuel tanks and cylinders
  • cellars or basements with no access to the outside
  • outdoors within 1 m of an escape route, door, window or ventilation opening

Other requirements in PAS 63100 that are useful to know before you get a quote:

  • Fire separation. An indoor battery location needs walls, ceilings and floors giving at least 30 minutes of fire resistance from the places listed above.
  • Ventilation. Any indoor location containing batteries needs fresh-air ventilation to outdoors.
  • Smoke detection. If a battery is in a place you rarely go, such as a store cupboard, it needs a smoke alarm or multi-sensor alarm there, interlinked with the alarms in the rest of the home.
  • Size limits. No single battery enclosure may hold more than 20 kWh. The total for a house is 40 kWh, or 80 kWh if the batteries are outdoors, in a detached garage or outbuilding, or in an attached garage or outbuilding with at least 60 minutes of fire separation.

PAS 63100 does not cover homes over 200 m² in floor area or high-risk residential buildings, so different rules may apply to large houses and some flats.

What if you already have a battery in the loft?

Amendment 4 is not retrospective, so it does not by itself require an existing battery to be moved. If you have a battery in the loft or on a landing, it is still worth asking the company that installed it, or a registered electrician, whether it was installed to the guidance that applied at the time and whether they would suggest any changes, such as interlinked smoke detection.

AFDDs: what has and has not changed

An AFDD (arc fault detection device) watches a circuit for the electrical signature of dangerous arcing, the kind caused by a loose connection or a damaged cable, and switches the circuit off before it can start a fire. They are made to BS EN 62606 and usually sit in the consumer unit.

AFDDs are a regular topic in articles about Amendment 4, but the rule that matters most was introduced earlier, in Amendment 2 (2022). As quoted in a GOV.UK technical bulletin, Regulation 421.1.7 says AFDDs shall be provided for single-phase AC final circuits supplying socket-outlets rated up to 32 A in:

  • higher risk residential buildings
  • houses in multiple occupation (HMOs)
  • purpose-built student accommodation
  • care homes

“For all other premises”, AFDDs on those circuits are recommended rather than required.

Neither the IET nor BSI lists AFDDs among the main changes in Amendment 4. NICEIC’s guide to Amendment 4 reports that the only change is to the wording of the first category: “higher risk residential buildings” has become “high rise residential buildings”, meaning residential buildings over 18 metres or more than six storeys. The requirement still applies to the same four building types.

On that reading, for an ordinary house or flat that is not an HMO and not in a high-rise building, AFDDs are still a recommendation. They can be a sensible addition, especially when a consumer unit is being replaced anyway, but be wary of anyone who tells you Amendment 4 means you must fit them. If an electrician recommends AFDDs, ask them to explain the benefit for your home and what it will cost, so you can make an informed choice.

Does Amendment 4 mean you need to upgrade?

No. The IET puts it plainly in Wiring Matters: “Standards are not retrospective”. An installation built to an earlier version is “not necessarily unsafe, even if it may not be to the current level of safety”. Upgrading to the current standard may improve safety, and you may choose to do it, “but it is not a requirement”.

The IET notes one exception: where new equipment is installed that is not compatible with the existing installation.

Where Amendment 4 does affect you is when work is done. New installations, additions and alterations should now be designed and installed to Amendment 4, and periodic inspections such as an EICR are carried out against the current standard. An inspection may note that older parts of your installation differ from today’s rules, but a difference is not automatically a danger.

What this means for you

  • No work planned? You do not need to do anything because of Amendment 4.
  • Thinking about a home battery? Expect it to go outdoors or in a garage or outbuilding rather than the loft. Ask the installer how the location meets PAS 63100, and whether you need new or interlinked smoke alarms.
  • Planning electrical work? Ask which version of BS 7671 the work is designed to. New work should now be to Amendment 4.
  • Choosing an electrician? Check they are registered with a Competent Person Scheme and up to date with the current regulations. Our guide to choosing a qualified electrician covers what to ask.
  • Worried about an old consumer unit? See when to replace your consumer unit and the difference between a fuse box and a consumer unit.
  • Buying a home? Read about getting an EICR when buying a house.

If you are unsure whether something you have been told about Amendment 4 is right, get in touch for general advice. If something in your home is not working as it should, our fault finding page explains how faults are traced. For any new circuits, battery installations or certification, use an electrician registered with a Competent Person Scheme.

Sources

Frequently asked questions

When did BS 7671 Amendment 4 come into force?

The IET and BSI published Amendment 4 on 15 April 2026, and it could be used from that day. The previous version, BS 7671:2018+A2:2022+A3:2024, was withdrawn on 15 October 2026. From that date Amendment 4 is the version that must be used.

Do I need to upgrade my electrics because of Amendment 4?

No. The IET is clear that standards are not retrospective. An installation built to an earlier version is not necessarily unsafe, and upgrading it to the current standard may improve safety but is not a requirement. Amendment 4 applies to new installations, additions and alterations, and to periodic inspection and testing.

Can I put a home battery in my loft?

Not under PAS 63100:2024, the BSI fire safety specification for home battery storage. It lists voids, roof spaces and lofts among the places batteries shall not be installed, along with bedrooms and escape routes such as landings, staircases and corridors. Its starting point is that batteries should be installed outdoors where practicable.

Are AFDDs now compulsory in houses?

Since Amendment 2 (2022), AFDDs have been required on socket-outlet circuits up to 32 A in high-rise residential buildings, houses in multiple occupation, purpose-built student accommodation and care homes, and recommended in all other premises. The IET and BSI do not list AFDDs among the main changes in Amendment 4, and NICEIC reports that only the wording of the high-rise category changed.

What else changed in Amendment 4?

Alongside the new chapter on stationary batteries, the IET lists a new section on functional earthing and bonding for IT and communications equipment, a new section on Power over Ethernet, and a major revision of the rules for medical locations. Amendment 3 (2024) has also been folded into the main document.